10.6.2 - Flashing light
Quick fl ashes
1 fl ash
1 second pause
1 fl ash
2 fl ashes
1 second pause
2 fl ashes
3 fl ashes
1 second pause
3 fl ashes
4 fl ashes
1 second pause
4 fl ashes
10.6.3 - Control unit
The LEDs on the control unit provide particular signals to report on the
normal operation and on possible faults; see Table 13.
LED ECSBus [A]
Off
On
One fl ash per second
2 long fl ashes
1 fl ash every 5 seconds
Series of fl ashes separated by
a pause
Quick fl ash
LED STOP [B]
Off *
On
Status
ECSbus error
Photocell activated
"Gearmotor force" limiting device activated
STOP input activated
TABLE 13 (fi g. 47)
Status
Fault
Serious fault
Everything OK
Input status variation
Robotics in "standby" mode
The same signal as for the fl ashing light, see Table 12.
ECSBus short circuit
Status
STOP input activated
Everything OK
During a manoeuvre the fl ashing light fl ashes every second; in case of
anomalies the light fl ashes at more frequent intervals (half a second); the
fl ashes are repeated twice with an interval of one second; see Table 12.
TABLE 12
Action
At the beginning of the manoeuvre the devices present do not cor-
respond with those recognised; check and eventually carry out the
learning procedure (10.3.3 "Recognition of other devices").
One or more devices may be faulty; check and, if necessary,
replace them.
At the start of the manoeuvre, one or more photocells do not
enable movement; check to see if there are any obstructions. Dur-
ing the movement if there is an obstruction no action is required.
During the movement, the gate experienced excessive friction;
identify the cause.
At the start of the manoeuvre or during the movement, the STOP
input was activated; identify the cause.
47
Action
Check that the unit is powered; check that the fuses have not
been activated; if this is the case check the cause of the fault
and replace them with other fuses with the same characteristics.
There is a serious fault; switch off the control unit for a few
seconds; if the status persists there is a fault and the electronic
board must be replaced.
Control unit works correctly
A variation to the status of the inputs: OPEN, STOP, activa-
tion of the photocells, or when the radio transmitter is used, is
normal.
Everything OK; when the control unit receives a command nor-
mal operation is restored (with a short delay).
An overload has been detected therefore the power to the
ECSBus switched off. Check by disconnecting the devices one
at a time.
To restore power to the ECSBus simply send a command, for
example with a radio transmitter.
Action
Check the devices connected to the STOP input
STOP input active
B
C
A
D
E
F
English – 23