––– STEP 10 –––
10.1 - ADVANCED SETTINGS
10.1.1 - Parameter settings via radio transmitter
The radio transmitter can be used to set a number of control unit operat-
ing parameters: there are eight parameters.
1) Pause time: the time for which the leafs remain open (in the case of
automatic closure).
2) Pedestrian opening: Pedestrian leaf opening mode.
3) Motor force: motor force over which the control unit recognises an
obstacle and inverts movement.
4) "OPEN" function: sequence of movements associated with each
"OPEN" command.
Parameters
NO.
1
2
Pause Time
3
4
1
2
Apertura pedonale
3
4
1
2
Forza motore
3
4
1
2
Funzione "OPEN"
3
4
(*) Factory setting
Parameters
NO.
1
2
3
4
Discharge on clos-
ing Motor 1
5
6
7
8
1
2
3
Discharge on open-
4
ing Motor 1
5
6
7
8
1
2
3
Discharge on clos-
4
ing Motor 2
5
6
7
8
1
2
3
4
Discharge on open-
ing Motor 2
5
6
7
8
(*) Factory setting
16 – English
FURTHER INFORMATION
Value
10s
20s (*)
40s
80s
Opening of 1 leaf to mid-travel
Total opening of 1 leaf (*)
Partial opening of 2 leafs to 1/4 of travel
Partial opening of 2 leafs to mid-travel
Low
Medium low (*)
Medium high
High
"Open", "Stop", "Close", "Stop"
"Open", "Stop", "Close", "Open" (*)
"Open", "Close", "Open", "Close"
Opening only
Value
No discharge (*)
0.1 s (Minimum)
0.4 s (Medium)
0.7 s (Maximum)
No discharge (*)
0.1 s (Minimum)
0.4 s (Medium)
0.7 s (Maximum)
No discharge (*)
0.1 s (Minimum)
0.4 s (Medium)
0.7 s (Maximum)
No discharge (*)
0.1 s (Minimum)
0.4 s (Medium)
0.7 s (Maximum)
5) Level of discharge of motor 1 on closing sets the duration of the "brief
inversion" of the motor after a closing manoeuvre, serving to reduce the
fi nal residual force.
6) Level of discharge of motor 1 on opening: sets the duration of the "brief
inversion" of the motor after an opening manoeuvre, serving to reduce
the fi nal residual force.
7) Level of discharge of motor 2 on closing sets the duration of the "brief
inversion" of the motor after a closing manoeuvre, serving to reduce the
fi nal residual force.
8) Level of discharge of motor 2 on opening: sets the duration of the "brief
inversion" of the motor after an opening manoeuvre, serving to reduce
the fi nal residual force.
TABLE 3
Action: operation to be performed at point 3 of the settings phase
Press T1 once
Press T1 twice
Press T1 three times
Press T1 four times
Press T2 once
Press T2 twice
Press T2 three times
Press T2 four times
Press T3 once
Press T3 twice
Press T3 three times
Press T4 four times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
TABLE 4
Actions to be performed
Press T1 once
Press T2 twice
Press T1 three times
Press T1 four times
Press T1 fi ve times
Press T1 six times
Press T1 seven times
Press T1 eight times
Press T2 once
Press T2 twice
Press T2 three times
Press T2 four times
Press T2 fi ve times
Press T2 six times
Press T2 seven times
Press T2 eight times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T3 fi ve times
Press T3 six times
Press T3 seven times
Press T3 eight times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
Press T4 fi ve times
Press T4 six times
Press T4 seven times
Press T4 eight times