3 INSTALLATION

3.1 Installation Guidelines

The controller SE5 Batch INLINE can only be used to measure pure, liquid and
!
water-like fluids (solids content ≤ 1%, viscosity max. 300 cSt with on-line calibration).
Observe pressure-temperature dependence according to the respective fitting materials.
P
16
bar
15
14
13
12
PVC + PP
11
10
9
PVDF
8
7
6
5
4
3
2
1
0
-30
-50
-10
Fig. 2 Pressure-Temperature-Diagram
Fitting type S030 installation guidelines
The pipe must be completely filled with the
liquid, i.e. air bubbles must not be present.
The flow sensor is not designed for gas flow
measurement.
The device must be protected from constant
heat radiation and other environmental
influences, such as direct exposure to
sunlight.
The
recommended
downstream straight pipe length should
respect 10xD in and 3xD out.
According to pipe's design, necessary
distances can be bigger or use a flow
straightener to obtain the best accuracy.
For more information please refer to EN ISO
5167-1.
8035
Application range for SE35 INLINE
PVDF (PN 10)
PVC (PN 10)
PP (PN 10)
+30
+10
+50
upstream
and
BATCH CONTROLLER SE35
+90
+70
+110
+130
The flow sensor can be installed in either
horizontal or vertical pipe.
The suitable pipe size is selected using the
diagram on the end pages. Pressure and
temperature ratings must be respected
according to to the selected fitting material.
(see fig. 2)
E-7-
T° C