Fig. 11
Fig. 12
Fig. 13
Fig. 14
1
10 Maintenance
10.3
Changing the horizontal lighting
Luminous elements or starters may only be
replaced by a qualified electrician or person
with experience in electrical engineering.
Unplug power plug !
Wear safety gloves when cleaning and ser-
vicing the device (risk of injuries).
Disconnect cabinet (see section 11).
-
Completely remove the cover (11-1).
-
-
Turn fluorescent lamp to unlock and remove it
downwards from the bracket (see fig. 12).
-
Insert new lamp and turn it to lock.
-
Position the cover and press, until it has com-
pletely engaged.
Start cabinet (see section 5).
-
We recommend a starter change with each
lamp change (see section 10.4).
10.4
Changing the starter
Disconnect cabinet (see section 11).
-
To change the starter, remove the fluorescent
-
lamp of the vertical (see section 10.2) or the hori-
zontal lighting (fig. 12, see section 10.3).
Press in faulty starter slightly (see fig. 13 or fig.
-
14) and turn in the direction of the arrow by a
quarter of a revolution.
-
Pull faulty starter out of the bracket and replace
with a new one.
Insert the fluorescent lamp again.
-
Start cabinet (see section 5).
-
45