BFT HIDE SL SMART BT A150 Instructions D'utilisation Et D'installation page 35

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 41
x2
***
0---
10--
Add. 1ch
Add. 2ch
Add. 3ch
Add. 4ch
erase 64
erase 1
( 0001 )
language
autoset
Control unit
software version
stat
vers
OK
bft . . .
+/-
No total manoeuvres(in hundreds)
- +
n. cycles
0000
OK
+/-
- +
No radio controldevices memorised
OK
00
n. remotes
+/-
- +
List of last 30 errors
err
OK
01. 3 3
02. 0 1
........
30. 1 5
+/-
0---
password
ACCESS MENUS Fig. 2
150-
1520
See PARAMETERS MENU
See LOGIC MENU
See RADIO MENU
If cancelled
ok
If not present
KO
If clone, it is disabled
dis
Diagnostics
code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
Ti e
STOP input activated
STOP
PHOT photocell input activated
PHOT
PHOT OP opening photocell input activated
PHOP
PHOT CL closing photocell input activated
PHCL
BAR safety edge input activated
BAR
Activation of edge input in BARC closure
BARc
Activation of edge input in BARO opening
BARo
SWC motor closing limit switch input activated
SWC
SWO motor opening limit switch input activated
SWO
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in
SET
order to acquire the torque required for movement.
WARNING! Obstacle detection not active
Photocell test failed
ER01
Safety edge test failed
ER02
Opening photocell test failed
ER03
Closing photocell test failed
ER04
8k2 safety edge test failed
er06
Board hardware test error
ER1x*
Reverse due to obstacle - Amperostop
ER3x*
Thermal cutout
ER4x*
ER70-ER71
Internal system supervision control error.
ER74-ER75
Consistency error of the control unit's parameters (Logics
ER72
and Parameters)
D-track parameter error
ER73
Autoset not correctly performed due to intervention of
01
external commands. Repeat the procedure
Travel less than the minimum required travel, about 50 cm.
02
The installation is too "resilient/oscillating". Tighten it by
adding a mechanical stop to the closure limit-switch (kit
03
code I100025 10005) before performing a further autoset.
* X = 0,1,...,9,A,B,C,D,E,F
10--
150-
ok
Switch on display
• Opening command
• ≥ 2 sec Manual transmitter programming as start
• Closure command
• ≥ 2 sec Manual transmitter programming as 2nd radio channel
• ≥ 5 sec Cancellation of remote controls
• Access menu
• ≥ 5 sec menu autoset
DESCRIPTION
1520
prg
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
Confirm/
Scroll up
Scroll down
Exit Menù
NOTES
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/logic setting
Check photocell connection and/or parameter/logic setting
Check safety edge connection and/or parameter/logic settings
- Check connections to motor
- Hardware problems with board (contact technical assistance)
Check for obstacles in path
Allow automated device to cool
Try switching the board off and back on again. If the problem persists,
contact the technical assistance department.
Pressing OK the detected settings are confirmed. The board will keep
on working with the detected settings.
The board settings must be checked (Parameters and Logics)
Pressing OK, the board will keep on working with D-track as a default.
An autoset is required
HIDE SL SMART BT A150-A300
35
-

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hide sl smart bt a300