Siemens SITRANS FUS1010 Guide Rapide page 47

Masquer les pouces Voir aussi pour SITRANS FUS1010:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LEVEL A
LEVEL B
Meter Type
2 Channel Flow
Dual Path Flow
1
Ch 1+2 Flow
Ch 1-2 Flow
This Menu Chart applies to:
MLFB - 7ME3531
7ME3532
Siemens Industry, Inc.
Industry Automation Division
CoC Ultrasonic Flow
Hauppauge, New York
USA
Web: www.usa.siemens.com
FUS1010 IP65 (NEMA 7) Installation Menu Chart
LEVEL C/D
Channel 1/2 Clamp-on Recall Site
Channel Setup
3
Pipe Data
4
Application Data
5
Install Xdcr
Operation Adjust
Flow/Total Units
Data Span/Set/Cal
Datalogger Setup
I/O Data Control
Diagnostic Data
LEVEL E (see manual)
Channel Enable
Create/Name Site
2
Site Security
Delete Site
Save/Rename Site
Pick Pipe Class
Select Pipe Size
Pipe OD (in)
Pipe Material
Wall Thickness
Liner Material
Liner Thickness
Liquid Class
UniMass Tables
Temp. Range
Pipe Config
Anomaly Diams
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value <in>
Install Complete
Empty Pipe Set
Zero Flow Adjust
Damping Control
Deadband Control
Memory/Fault Set
Memory Delay (s)
Flow Vol. Units
Flow Time Units
Flow Disp. Range
Flow Disp. Scale
Total Vol. Units
Totalizer Scale
Total Resolution
Totalizer Mode
Batch/Sample Tot
Reset Totalizer
Span Data
Set Alarm Levels
Calib. Flowrate
Datalogger Mode
Datalogger Data
LogTimeInterval
Datalogger Events
Analog Out Setup
Relay Setup
Analog Inp Setup
Flow Data
Application Info
Liquid Data
Site Setup Data
Test Facilities
Print Site Setup
Date/Site Created:
LEVEL F
Enter From List
No/Yes
Enter Site Name
On/Off
Enter From List
Enter/Clear Site Name
Enter From List
Enter From List
Numeric Entry
Enter From List
Numeric Entry
Enter From List
Numeric Entry
Select Liquid
Estimated Vs M/S
Viscosity <cS>
Density S.G.
Enter From List
Enter From List
Enter From List
Numeric Entry
Enter From List
Enter From List
Enter From List
Enter From List
View Only
View Only
View Only
No/Install
Enter From List
Enter From List
Time Average / SmartSlew
Numeric Entry
Fault/Memory
N/A
Enter From List
Enter From List
Autorange/High
Enter From List
Enter From List
Enter From List
Enter From List
Enter From List
Numeric Entry
Yes/No
Enter From List
Enter From List
Intrinsic
Kc
MultiPoint
Enter From List
Enter From List
Enter From List
Enter From List
Enter From List
Relay 1 / Relay 2
Enter From List
Enter From List
Enter From List
Enter From List
Enter From List
Enter From List
No/Yes
View Only
LEVEL G
Enter from List
Numeric Entry
Numeric Entry
Numeric Entry
Select Install