General Data - Burkert 8025 Manuel D'utilisation

Masquer les pouces Voir aussi pour 8025:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

180
Fig. 3 :
Dimensions [mm] of the SE35 electronic module
6.2.2

general data

Fluid temperature
The fluid temperature may be restricted by the
fluid pressure or by the material of the fitting
used: See Fig. 4 or Fig. 5 and the Operating
Instructions of the fitting used.
The maximal fluid temperature may be
restricted by the maximal operating temper-
ature of the batteries used
10
FLOW
ENTER
0....9
88
95
English
Type 8025 / SE35, battery powered
Technicaldata
Fluid pressure
The fluid pressure may be restricted by the
fluid temperature or by the material of the
fitting used: See Fig. 4 or Fig. 5 and the
Operating Instructions of the fitting used.
Flow rate
measurement
• Measurement range
• 0,3 to 10 m/s
• Measurement
• ± 1 % of the measured value (at the
deviation, if the K
flow rate of the Teach-in)
factor is determined
with the Teach-in
function
• Measurement
• ± 2,5 % of the measured value
deviation, if the K
factor of the fitting
used is entered
manually
• Linearity error
• ± 0,5 % of the full scale
• Repeatability
• ± 0,4 % of the measured value
Power supply
4 1.5-V-batteries, connected in series
Minimum charge: 4 years at 20° C in the
reasonably expected conditions of use
of the device and from the date of manu-
facture of the device.
Determined in the following reference conditions: fluid = water,
1)
water and ambient temperatures = 20 °C, upstream and down-
stream distances respected, appropriate pipe dimensions.