Mechanical Data - Burkert 8025 Manuel D'utilisation

Masquer les pouces Voir aussi pour 8025:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Pressure Equipment Directive (flowmeter 8025): article 3§3 of the
directive 97/23/CE. The device can only be used in the following
cases (depending on the max. pressure, the DN of the pipe and
the fluid):
type of fluid
Fluid group 1, par. 1.3.a
Fluid group 2 par. 1.3.a
Fluid group 1 par. 1.3.b
Fluid group 2 par. 1.3.b
• Pressure Equipment Directive (electronic module SE35): Refer to
the Operating Instructions of the sensor-fitting used.
6.2.1

mechanical data

part
Housing / seal
Cover with lid / seal
Front foil
M20x1.5 screw plugs / seal
8
pressure resistance conditions of
the 8025
only DN25
DN ≤ 32
or DN > 32 and PNxDN≤≤ 1000
DN ≤ 25
or DN > 25 and PNxDN≤ 2000
DN ≤ 400
material
PC / NBR
PC / silicone
Polyester
PA / neoprene
English
Type 8025 / SE35, battery powered
Technicaldata
part
Screws
Nut
Flow sensor (exposed to the
fluid) / seal (only with 8025)
Axis and bearings of the paddle
wheel.
R=90
QA PASSED
49.5
Fig. 2 :
Dimensions of 8025 in mm
material
Stainless steel
PC
PVDF / FKM
ceramic
FLOW
ENTER
0.....9
88
136