Alarm dwell times
From ALARM menu, press
TIME submenu.
If multiple inputs are displayed on alarm, the dwell time of
each input is determined. The duration is between 1 and 60
seconds.
Select the video input whose time has to be modified by
pressing the relevant number (1/16).
Modify the duration by pressing
C
and
(one second decrease).
M
copies the value of the first input to all the others.
P
confirms the modifications and returns to the previous
menu
Reset of alarm condition
From ALARM menu, press
Enable or disable each type of reset pressing
If TIME AUTO RESET is enabled, the keys
time, from 5 seconds to 1 hour after the last alarm signal.
P
confirms the modifications and returns to the previous menu.
Alarm recognition
From ALARM menu, press
Each output can be set in order to acknowledge only a group of alarm contacts.
This allows the alarm to be displayed on only one monitor, while the others
perform their normal sequences.
Select each of the 4 outputs, and proceed with the configuration.
In the shown example, the output number 3 recognises only the alarm conditions
on contacts 1, 2 and 4. Any alarm on these contacts generates a sequence cycle
(on the output 3) with the corresponding alarm groups. Any alarm condition on
the other contacts is ignored.
Press the corresponding number (1/16) to enable (
acknowledgement of a contact.
E
enables the recognition of all contacts;
P
confirms the modifications and returns to the preceding menu.
3
to access ALARM DWELL
E
(one second increase)
4
to access the ALARM RESET submenu.
1
2
,
U
and
5
to access the ACKNOWLEDGEMENT submenu.
X
C
disables it.
Input to be set
Dwell time
3
and
.
D
are used to select the
) or disable (
) the
-
Page 22
TIME CYCLE
------------------------
1.02
9.01
Push 1/16
2.05
10.01
to select
>3.02< 11.01
4.01
12.01
ENT.Plus
5.01
13.01
CLR.Minus
6.01
14.01
7.01
15.01
M/A.Copy
8.01
16.01
first
------------------------
PROG.End
ALARM RESET
------------------------
1. Keyboard
: YES
2. External
: NO
3. Auto reset : YES
after 20 sec.
to change delay
áâ
------------------------
PROG.End
ACKNOWLEDGEMENT
------------------------
1. Output no.1
2. Output no.2
3. Output no.3
4. Output no.4
------------------------
PROG.End
ACKNOWLEDGEMENT
------------------------
OUTPUT NO.3
1.X
9.-
Push 1/16
2.X 10.-
to toggle
3.- 11.-
4.X 12.-
ENTER.All ON
5.- 13.-
CLEAR.All OFF
6.- 14.-
7.- 15.-
8.- 16.-
PROG.End