Water outlet
When cooling, you do not need to install a drainage hose. During the
cooling process, the device removes water from the air; this water
evaporates and is then transferred outdoors with the hot air. Ensure
that the rubber cap (1) is placed on the water drainage point.
A drainage hose is also not required when
heating; it does, however, increase the
effectiveness of the heating function.
Remove the cap on the water outlet on the
side of the unit (1) and connect a suitable
drainage hose to the outlet; the end of this
should then be placed in a bucket or drain.
If you wish to humidify, remove the air outlet
hose. Connect a water outlet hose to the
drainage point (1) and run the hose to a
collection reservoir or a drain. The
Multiclima does not have an in-built water
tank for the moisture!
MAINTENANCE
Always switch the unit off and remove the plug from the socket before
carrying out maintenance. Regular cleaning is vital in order to keep the
Multiclima in good working order!
removed if necessary and cleaned with a damp (not wet!) cloth and a
mild cleaning agent. Dry afterwards with a soft cloth.
28
The air filters (active carbon
filters) on the left hand side of
the unit can easily be
removed by sliding the frame
either left or right. Clean by
gently vacuuming using the
brush attachment on the
vacuum cleaner.
The condenser and
humidifier can be found
behind the air filters. Clean
them in the same way.
The housing can be

Publicité