Connecting the LS100 to the programming output of the command station
If the switch decoder is programmed via the programming output of the command
station, we recommend complete programming before installation.
To program the address and features, you need a command station
LZV100 / LZ100, a manual control LH100 or LH90, and a 16V AC transformer to
supply the LZV100 / LZ100. The LS100 is programmed via the programming
output of the command station LZV100 / LZ100.
Connect terminals J and K as well as the () terminals for the AC power supply of
the LS100 to the programming output (terminals P and Q) of the command station
LZV100 / LZ100.
Change to the programming mode as described in the operating manual of the
manual control LH100 (LH90).
Programming the point address
Change to the programming mode as described above.
Let us assume that you want to program the LS100 to the point addresses 9, 10,
11, and 12. Select 1 as the register to be programmed since the address is stored
here in the LS100 (see Table 1). Enter one of the four point addresses to which
you want to program the LS100 at the LH100. In our example, this would be 9 or
10 or 11 or 12.
+
+