xChargeIn
DIP switch
DSW1.6
DSW1.7
DSW1.8
DSW1.6
DSW1.7
DSW1.8
Get IP address via DHCP server - DSW2.1 to DSW2.4
DIP switch
DSW2.1
DSW2.2
DSW2.3
DSW2.4
Set fixed IP address - DSW2.1 to DSW2.4
DIP switch
DSW2.1
DSW2.2
DSW2.3
DSW2.4
Installation manual V1.01
© EATON
Current
25 A
32 A
Function
By default, the charging process is carried out
independently by the charging station without a
higher-level control system.
The charging station attempts to obtain an IP
address via DHCP server, if needed. This also
corresponds to the basic settings for charging
stations without network connection.
Not valid for xChargeIn M Series.
Function
If there are several charging stations in a net-
work, an addressing of the charging stations is
necessary.
The last two digits of the IP address
(192.168.25.xx) can be specified with the DIP
switches DSW2.1 to DSW2.4. Each DIP switch
has a specific value when it is set to "ON". A
DIP switch set to "OFF" has the value 0.
DSW2.1 = ON = value: 1
DSW2.2 = ON = value: 2
DSW2.3 = ON = value: 4
DSW2.4 = ON = value: 8
The address is obtained by adding the values
of the DIP switches and increasing the result
by 10:
Sum of the DIP switch values + 10
Thus, the addresses 11 to 25 are settable.
Not valid for xChargeIn M Series.
Configuration
Illustration
Illustration
Illustration
Example of IP address
xxx.xxx.xx.21
DSW2.1 = ON = 1
DSW2.2 = ON = 2
DSW2.3 = OFF = 0
DSW2.4 = ON = 8
Address =
1 + 2 + 0 + 8 + 10 = 21