7

Connections and wiring

7.1

Connection overview

The following illustration shows a connection overview with the covers open.
Fig. 7-15: Connection overview
DSW1
Shd
USB
WARNING!
Risk of electric shock and fire hazard!
● For terminals X1-X4 (Ethernet connections as well as terminals for en-
● The connection panel is never permitted to be left open unattended. Be-
Installation manual V1.01
© EATON
F1
... Fuse holder
2
... Mains connection phase conduc-
tor 2
N
... Mains connection neutral conductor
... DIP switch
T1
... Service button
X1
... Enable input
... Shield clamp (mass for ETH)
X4
... Ethernet1 connection (LSA+® ter-
minals)
... USB interface
abe input and switch contact output), only voltages and circuits are per-
mitted to be connected which have a safe separation to dangerous volt-
ages (for example sufficient insulation).
Supply the terminal for the switch contact output (X2) exclusively from
voltage sources which have a protective extra-low voltage.
fore leaving the charging station, the connection panel cover must be
mounted.
Connections and wiring
1
... Mains connection phase conduc-
tor 1
3
... Mains connection phase conduc-
tor 3
PE
... Mains connection earthing conduc-
tor
DSW2
... DIP switch
LED
... Status LED
X2
... Switch contact output
X3
... Ethernet2 connection (RJ45)
SIM
... SIM card slot (optional)