xChargeIn
7.4.1

Connection diagram

Fig. 7-17: Connection diagram X1
7.5
Switch contact output X2 (except xChargeIn A Series)
The switch contact output X2 (signal contact) is a potential-free relay contact
and can be used as a charging status display (default use) or contactor mon-
itoring. The terminal is designed as a spring-type terminal.
The use of the switch contact output must be activated with a DIP switch set-
ting (DSW1.2 to ON).
For further information see
Charging status display
Open
Closed
Contactor monitoring
Open
Closed
Installation manual V1.01
© EATON
DSW1.2 ON means X2 is used as contactor monitoring.
DSW1.2 OFF means X2 is used as the charge status indicator.
Enable contact
Enable contact
8.1 DIP switch
settings.
State of the charging station
Vehicle is connected, charging station not in
operation or error.
Charging station is ready for operation and
no vehicle is connected.
State of the charging station
No error.
A switch contact of the contactor is stuck.
Connections and wiring
35