3. Check whether the DGEA fulfils the following conditions:
The cantilever moves through the complete intended positioning cycle.
The cantilever stops as soon as it reaches a limit switch.
If the proximity sensors do not respond, è operating instructions and the
chapter Eliminating malfunctions".
4. Start test travel limited to low dynamics.
5. Check these points on your installation.
The cantilever moves through the complete intended positioning cycle.
The cantilever axis behaves overall as expected.
In the case of deviations from the nominal behaviour:
6. Conclude the test travel immediately.
7. Check these points on your installation:
Motor
Motor mounting kit
Mechanical mounting
Electrical connections
For further tests read the test points in the chapter Eliminating malfunctions".
If the test run is without malfunction:
8. Repeat the test run several times with the speed increasing in stages until the
desired operating speed is reached.
9. Exit the test run.
For changes in the effective load:
·
Make sure that the limit values for all loads are not exceeded.
Festo DGEA−... 0904b English