Technical Data; Conformity; Standards; Operating Conditions - Burkert 8694 Guide Rapide

Masquer les pouces Voir aussi pour 8694:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electrical connection
(cable gland or circular
plug-in connector)
Pressure limiting valve
Communications interface
DIP Switches
Additional exhaust air port
(label: 3.1)
only for Type 23xx and 2103
with pilot-operated control
system for high air output
(actuator size ø 130)
Fig. 2:
Structure 2
8
LED
Exhaust air port
(label: 3)
Pilot air port
(label: 1)
Keys
Pilot air outlet only for
series 26xx and 27xx
Air intake filter
english
Type 8694
Technical data
6.
Technical DaTa

6.1. conformity

In accordance with the EC Declaration of conformity, the positioner
Type 8694 is compliant with the EC Directives.

6.2. standards

The applied standards, which verify conformity with the EC Direc-
tives, can be found on the EC-Type Examination Certificate and / or
the EC Declaration of Conformity.
6.3. operating conditions
Warning!
solar radiation and temperature fluctuations may cause mal-
functions or leaks.
• If the device is used outdoors, do not expose it unprotected to
the weather conditions.
• Ensure that the permitted ambient temperature does not exceed
the maximum value or drop below the minimum value.
Ambient temperature
0 – +60 °C
Protection class
IP65 / IP67 according to EN 60529
(only if cables, plugs and sockets have
been connected correctly
and in compliance with the exhaust air
concept in chapter "8.3. Pneumatic con-
nection of the positioner").

Publicité