There will be an automatic pressurising
up to 4 bars. The pressure inside the
pressure chamber will be verified per-
manently by the electronics and regu-
lated, if necessary. The display shows
the given cooling time (c) which then
counts down to 00:00.

8.5 Opening of the pressure chamber

In order to attain a complete cool down
of the thermoforming blank the valve
at the tension ring (12) is to be opened
slightly after 2/3 of the adjusted cooling
time. Through this the warm air inside
the piston will be released and replaced
by cool air due to the pressure regula-
tion of the electronics. After the cool-
ing time has elapsed there will be an
acoustic signal (indication in the display
(c) will blink).
Pull the heating handle (5) again as
far as it will go and maintain it in this
position (approx. 2–3 seconds) until the
pressure is relieved.
36
Then swivel the pressure chamber into
its original position by leading back
the activation lever (34). Swivel out
the plate reception (11) at the corre-
sponding handle (10) and remove ten-
sion ring and thermoformed result.
The display (2) will show the last used
programme; the scanning device (1) is
ready for a new thermoforming pro-
cess.

9. Deviation to the rule

9.1 Modification of given times

Scanned times may be prolonged or
With the same working steps the cool-
shortened individually, if required.
ing time can be modified in steps of
10 seconds by max. 70 seconds.
Info
The performance of the heating
might decrease slightly after 1000
operating hours. By prolonging
the heating times by 5–10 seconds
optimum thermoforming results
can be attained again. The times
given by the barcodes are aver-
For identification of the modified
age times and designed for gen-
parameters the display will show a +
eral use. In case of extreme under-
resp. a – sign. The degree of deviation
cut areas or very high models a
will be shown by a scale at the bottom
prolongation of the heating time
of the display.
can optimise the results.
Modified values have to be confirmed
After having scanned the pre-adjusted
by pressing the OK key (f).
material parameters (see paragraph
8.1) the heating time (1 x) or the cool-
ing time (2 x) can be selected by press-
ing the menu key (j). There will be an
arrow in the display in front of the cho-
sen time.
All further working steps correspond
to 8.2.
The heating time can be modified posi-
tively and negatively in steps of 5 sec-
onds. For this press the menu keys (e/i)
according to the key description. The
max. deviation from the scanned time
is 35 seconds.