Connection blocks Control board A
X1
Power supply to external loads,
1
e.g. electro-mechanical lock or radar detector
4
1+2 = 24 VAC, 2+4 = 12 VAC.
2
Drive unit disabling contact for e.g. smoke detector input;
5
jumper if not used
6
- 24 VDC
Power supply to external loads,
34
+ 24 VDC
e.g. electro-mechanical lock or radar detector (max. 400 mA)
35
X2
31
24 V
Secondary side, transformer
32
12 V
0 V
33
X3
36
Primary side, transformer
37
X4
N
38
Incomimg power supply 230 VAC +-10%, 50/60 Hz
L1
39
X5
U
40
V
Motor
41
W
42
43
Capacitor
6µF
44
X6
16
„Door open" limit switch
17
GND
18
+24 VDC
19
„Door closed" limit switch (cam)
20
Switches off the hinge-side safety sensor (e.g.IRS)
21
X7
Automatic
13
OFF (GND)
12
Permanent open
11
8
Activators (internal detector, external detector, IRS sensor on opposite hinge-side)
7
Hinge-side safety device (e.g. IRS sensor);
15
jumper if not used
14
C
Electro-mechanical lock:
27
Floating contact (change over contact)
26
NO
fixed pulse duration of 1 sec.
25
NC
X8
5-pin interface block for connection cable
modules for coordinated double-leaf operation
Control module B (master/ active leave) controls
module A (slave/ inactive leave)
R4
Hold open time 0-30sec.
ED 200
L1
N
4
1
37
36 39
38
X5
44
X1
X3
X4
43
42
41
40
A
X6
21
20
19
18
X7
17
16
26
27
14
15
7
8
11
12
13
Solenoid valve
Programme switch

Tecnical data

Power supply:
Fuse F2:
Fuse F3:
,
linking two control
.
GB
230 VAC ±10%, 50/60 Hz
T 0.8 A at 24 VAC
T 0.8 A at 12 VAC
max. 700 mA
47