Starting Operation; High-Pressure Hose, Spray Gun And Separating Oil; Control Panel Indicators - Titan Performance 1650e Série Mode D'emploi

Masquer les pouces Voir aussi pour Performance 1650e Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.

Starting operation

4.1
High-pressure hose, spray gun and
separating oil
1. Screw the high-pressure hose (2) to the coating material
outlet (Fig. 4, Item 1).
2. Screw the spray gun (3) with the selected tip onto the
high-pressure hose.
3. Tighten the union nuts at the high-pressure hoses firmly
so that coating material does not leak.
2
4. Remove the oil cup cap with a straight-slot screwdriver.
5. Fill the oil cup with Piston Lube (Fig. 5) until the oil gauge
(4) is showing that it is full.
Piston Lube prevents increased wear and tear to
the packings.
Attention
6. Replace oil cup cap.
7. Press oil button 2-5 times to prime the oiler. Press once
for every eight hours of usage to lubricate the fluid section.
Performance Series 1650e
3
1
GB
4.2

Control Panel Indicators

The following is a description of the control panel indicators.
Service
Indicator
Pressure Indicator
The pressure indicator shows the current operating pressure of
the sprayer. It has three different indications: blinking yellow,
solid yellow, and solid green.
Blinking Yellow
When the pressure indicator is blinking yellow, the sprayer is
operating between 0 and 1.4 MPa (14 bar). A blinking yellow
pressure indicator means:
• The sprayer is plugged in and turned "ON"
• The sprayer is at priming pressure (little or no pressure)
• It is safe to move the relief valve between positions
• It is safe to change or replace the spray tip
i
If the pressure indicator begins blinking yellow
when the pressure control knob is set at a higher
pressure and the relief valve is in the SPRAY
position, either the spray tip is worn or the
sprayer is in need of service/repair.
Solid Yellow
When the pressure indicator is solid yellow, the sprayer is
operating between 1.4 MPa (14 bar) and 12 MPa (120 bar). A
solid yellow pressure indicator means:
• The sprayer is at the proper pressure setting for spraying
stain, lacquer, varnish, and multi-colors
27
Starting operation
4
Pressure
Indicator

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

0558773

Table des Matières