Cleaning The High-Pressure Filter; Cleaning Airless Spray Gun; Cleaning The Inlet Screen - Titan Performance 1650e Série Mode D'emploi

Masquer les pouces Voir aussi pour Performance 1650e Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cleaning the unit (shutting down)
8.2

Cleaning the high-pressure filter

Clean the filter cartridge regularly.
A soiled or clogged high-pressure filter can cause a poor spray
pattern or a clogged tip.
1. Turn the pressure regulator knob into the black zone until
it stops (no pressure).
2. Open the relief valve, valve position PRIME
(k circulation).
3. Switch the unit OFF.
Unplug the power plug from the outlet.
4. Unscrew the filter housing (Fig. 10, Item 1). with a strap
wrench.
5. Pull the filter cartridge (2) from the bearing spring (3).
6. Clean all the parts with the corresponding cleaning agent.
If necessary, replace the filter cartridge.
7. Check the O-ring (4), replace it if necessary.
8. Place the bearing ring (5) against the bearing spring (3).
Slide the filter cartridge (2) over the bearing spring.
9. Screw in filter housing (1) and tighten it as far as possible
with the strap wrench.
1
2
8.3
Cleaning the Airless spray gun
1. Rinse Airless spray gun with an appropriate cleaning
agent.
2. Clean tip thoroughly with appropriate cleaning agent so
that no coating material residue remains.
3. Thoroughly clean the outside of the Airless spray gun.
Intake filter in Airless spray gun (fig. 11)
1. Pull the bottom of the trigger guard forward (1) so that it
comes loose from the handle assembly (5).
2. Loosen and remove the handle assembly (5) from the gun
head (2).
3. Turning clockwise, unscrew the filter (4) from the gun body
(2).
i
Left-handed threads require turning the filter
clockwise to remove.
GB
4. Turning counterclockwise, screw the new or cleaned filter
into the gun body.
5. Make sure all the parts are clean and the handle seal (3)
is in position inside the gun head.
6. Thread the handle assembly (5) into the gun head (2) until
secure.
7. Snap the trigger guard (1) back onto the handle assembly
(5).
8.4

Cleaning the inlet screen

5
The inlet screen will clog and must be cleaned at least once a
day.
1. Remove the retaining ring (3) from the foot valve (1)
housing.
3
2. Remove the inlet screen (2) from the foot valve housing
(1).
3. Clean thoroughly with the appropriate solvent.
4
32
1
1
2
3
Remedy in case of faults
2
4
3
5
Performance Series 1650e

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

0558773

Table des Matières