Troubleshooting Guide; Options And Accessories - Hatco Intelligent Toast-Qwik ITQ Série Manuel D'installation Et D'utilisation

Masquer les pouces Voir aussi pour Intelligent Toast-Qwik ITQ Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING GUIDE

WARNING
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
Symptom
Toast too light.
Toast too dark.
Unit toasts on one side only. Wrong program key/menu item selected
Toaster
trips
the
circuit
breaker or GFCI.
Conveyor doesn't move.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please
contact the nearest authorized Hatco Service agency or Hatco
for assistance. To locate the nearest Service agency, log onto
the Hatco website at www.hatcocorp.com and click on
Find Service Agent, or contact the Hatco Parts and Service
Team at:
Telephone: 800-558-0607 or 414-671-6350
e-mail:
partsandservice@hatcocorp.com
Fax:
800-690-2966 or 414-671-3976

OPTIONS AND ACCESSORIES

Food Paddle
a food paddle is available for
use when toasting/cooking
food product during "In and
Out" mode.
Probable Cause
Wrong program key/menu item selected
on touchpad control.
Wrong program key/menu item selected
on touchpad control.
on touchpad control.
Heating element defective.
Circuit breaker is not sized properly for the
toaster.
Wiring fault inside toaster.
Bread slices or buns jammed in conveyor
track.
ELECTRIC SHOCK HAzARD: Put unit in standby, allow to
cool, turn OFF power switch, and unplug power cord
before performing cleaning, adjustments, maintenance, or
attempting to clear a jam.
Select the correct program key/menu item for desired
toasting results.
Select the correct program key/menu item for desired
toasting results.
Select the correct program key/menu item for desired
toasting results.
Visually check the heating element inside the toaster
during operation. The heating element should glow
red. If the element does not glow, Contact authorized
Service agent or Hatco for assistance.
Check circuit breaker for proper sizing.
Contact authorized Service agent or Hatco for
assistance.
Turn off unit, wait for unit to cool, and remove bread
product jamming the conveyor.
12
English
WARNING
Corrective Action
Form No. ITQm-0214

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Itq-1750-2cItq-1000-1c

Table des Matières