Troubleshooting Guide; Corrective Action - Hatco KRAMPOUZ KGRDG Série Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
WARNING
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to explosion
or burn.
Symptom
Unit turned "On", but no heat.
Unit not hot enough.
Unit too hot.
Unit not working at all.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please contact the nearest Authorized Hatco Service Agency or Hatco for
assistance. To locate the nearest Service Agency, log onto the Hatco website at www.hatcocorp.com, select the Support pull-
down menu, and click on "Find A Service Agent"; or contact the Hatco Parts and Service Team at:
Telephone: 800-558-0607 or 414-671-6350
e-mail:
support@hatcocorp.com
Form No. KGRDGM-0120
Probable Cause
Safety thermostat shut down unit after flame
went out.
Temperature Control, burner system, pressure
regulator, or safety thermostat defective.
Temperature Control setting too low.
Temperature Control not calibrated properly.
Temperature Control setting too high.
Temperature Control not calibrated properly.
Unit not turned on.
Gas shutoff valve in closed position.
Temperature Control, burner system, pressure
regulator, or safety thermostat defective.

TROUBLESHOOTING GUIDE

Turn Temperature Controls to OFF position, close gas
shut-off valve, and allow unit to cool before performing
any cleaning, adjustments, or maintenance.
Refer to the OPERATION section of this manual:
• Perform "Shutdown" procedure.
• Wait five minutes for gas buildup to clear.
• Perfom "Lighting the Burners" procedure.
If unit still does not heat, perform "Shutdown" procedure and
contact Authorized Service Agent or Hatco for assistance.
Contact Authorized Service Agent or Hatco for assistance.
Turn Temperature Control counterclockwise to increase the
temperature setting.
Contact Authorized Service Agent or Hatco for assistance.
Turn Temperature Control clockwise to decrease the
temperature setting.
Contact Authorized Service Agent or Hatco for assistance.
Review the "Lighting the Burners" and "Operating the Unit"
prodedures in the OPERATION section of this manual.
Open the gas shutoff valve, and perform the the "Lighting
the Burners" and "Operating the Unit" prodedures in the
OPERATION section of this manual.
Contact Authorized Service Agent or Hatco for assistance.
13
WARNING

Corrective Action

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Krampouz kgrdg-2513

Table des Matières