Troubleshooting Guide - Hatco FSCD Série Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
WARNING
This unit must be serviced by trained and qualified
personnel only. Service by unqualified personnel may lead
to electric shock or burn.
Symptom
Xenon bulb not working.
Unit operates, but is not circulating air
inside cabinet.
Unit is plugged in, but nothing works.
Unit is not producing any "hot air" inside
cabinet.
Unit is heating, but is not producing
"Lo H20" not
humidity inside cabinet.
flashing on display and unit is full of
water.
Unit is heating, but is not producing
"Lo H20"
humidity inside cabinet.
flashes on display and unit is full of
water.
Error Codes
The following error codes may appear on the CaBINET
TEmPERaTURE display to indicate an error in the operating
condition of the unit.
LO H20 = Low water probe does not detect water. Refill water
reservoir — refer to instructions in oPERaTIoN section of this
manual.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please contact the nearest authorized Hatco Service agency or
Hatco for assistance. To locate the nearest Service agency, log onto the Hatco website at www.hatcocorp.com and
click on Find Service Agent, or contact the Hatco parts and Service Team at:
Telephone: 800-558-0607 or 414-671-6350
e-mail:
partsandservice@hatcocorp.com
Form No. FSCDm-1016
probable Cause
Bulb loose or defective.
Blower motor(s) defective.
The correct voltage may not be supplied to
blowers.
No power to unit.
Power
cord
connections
disconnected.
Power cord is damaged.
Defective PoWER oN/oFF (I/o) switch.
Safety high-limit is tripped or open.
Incorrect voltage supplied to heating element.
Blower motor(s) not working.
air heating element(s) defective.
Incorrect voltage supplied to water heating
elements or heating elements defective.
When using distilled water, no minerals are being
sensed by low water probe.
Low water protection system is malfunctioning. Contact authorized Service agent or Hatco for
13

TROUBLESHOOTING GUIDE

ELECTRIC SHOCK HAzARD: Turn OFF power switch,
unplug power cord, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.
Re-install or replace Xenon bulb.
Contact authorized Service agent or Hatco for
assistance.
Contact authorized Service agent or Hatco for
assistance.
Check electrical receptacle and verify that power
supply matches specifications on unit. If receptacle
is not working, check circuit breaker and reset, or
plug unit into a different known working receptacle.
are
loose
or
Contact authorized Service agent or Hatco for
assistance.
Contact authorized Service agent or Hatco for
assistance.
Contact authorized Service agent or Hatco for
assistance.
Contact authorized Service agent or Hatco for
assistance.
Contact authorized Service agent or Hatco for
assistance.
Contact authorized Service agent or Hatco for
assistance.
Contact authorized Service agent or Hatco for
assistance.
Contact authorized Service agent or Hatco for
assistance.
on initial fill, add one teaspoon of salt to the water
reservoir.
assistance.
E1 = air temperature sensor malfunctioning. Contact authorized
Service agent or Hatco for assistance.
E2 = Humidity temperature sensor malfunctioning. Contact
authorized Service agent or Hatco for assistance.
WARNING