INSTALLATION

General

The Flav-R-Savor
Convected Display Cabinets are shipped
®
with most components installed and ready for operation. Care
should be taken when unpacking shipping carton to avoid
damage to unit and the components enclosed. The following
installation instructions must be performed before connecting
electricity and operating the cabinet.
WARNING
ELECTRIC SHOCK HAzARD: Unit is not weatherproof.
Locate unit indoors where ambient air temperature is a
minimum of 70°F (21°C).
FIRE HAzARD:
• Locate unit a minimum of 1" (25 mm) from combustible
walls and materials. If safe distances are not
maintained, discoloration or combustion could occur.
• Do not place anything on top of unit.
Locate unit at proper counter height in an area that is
convenient for use. Location should be level to prevent unit
or its contents from falling accidentally and strong enough
to support the weight of the unit and contents.
The National Sanitation Foundation (NSF) requires that
units over 36" (914 mm) in width or weighing more than
80 lbs. (36 kg) either be sealed to or raised above the
installation surface. If unit cannot be sealed at the point of
use, 4" (102 mm) legs are included to allow for proper
cleaning access below unit.
1. open and remove the top and sides of the shipping carton.
NOTICE Do not remove unit from carton before
installing legs.
NOTE: Humidified units have a drain valve installed on the
bottom of the unit. The valve will be crushed if the unit
is removed from the carton and set down before
installing the legs.
2. Perform the "assembling the Unit" procedure in this
section. Two or more people are required for this
procedure.
3. Remove any remaining tape and protective film from all
surfaces of unit.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
ImPoRTaNT oWNER INFoRmaTIoN section for
details.
4. Place the unit in the desired location.
• Locate the unit in an area where the ambient air
temperature is constant and a minimum of 70°F (21°C).
avoid areas that may be subject to active air movements
or currents (i.e., near exhaust fans/hoods and air
conditioning ducts).
• make sure the unit is at the proper counter height in an
area convenient for use.
• make sure the countertop is level and strong enough to
support the weight of the unit and food product.
5. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See the
SPECIFICaTIoNS section for details.
CAUTION

Assembling the Unit

Use the following procedure to install the legs, top shelf (glass
or stainless steel), and side air deflectors on the unit. These
items are secured to the base shelf for shipping. Removal of
other components is required to prevent damage when tipping
the unit for leg installation.
1. Remove the curved front glass panel.
a. Loosen the thumbscrews holding the curved glass
retaining clips on each side of the panel.
b. Rotate the curved glass panel partially forward and lift
straight up and off the fixed hinge. Discard the rubber
packing strips.
Curved Front
Glass Panel
Rotate forward.
Removing the Curved Front Glass Panel
2. Remove the plastic bags containing the 4" (102 mm)
adjustable legs, the two side air deflectors, and the leg skirt
from inside the unit.
3. Remove the top shelf (glass or stainless steel) from inside
the unit. If the top shelf is glass, there also is a vent panel
to remove.
4. Remove the front air deflector from the front edge of the
base inside the unit.
5. Carefully remove the stone base shelf by lifting it up and off
the locating pegs at the rear of the base.
Do not lay unit on the side with the control panel or on the
front of a curved glass unit. Damage to unit could occur.
6
English
Fixed
Hinge
Lift straight up.