Fig. 4.2.7: Two dots of X60 adhesive prevent mechanical influences acting on the
fibers and protect the optical strain gage
Fig. 4.2.8: Removing the hinge. The installation is now capable of measurement.
Now is the time to fit the protective cover.
Now the hinge can be removed and installation protection fitted. As Z70, like
all cyanacrylates, should be protected against moisture, HBM recommends
using a protective cover.
We recommend an initial layer of elastic SG250 silicone rubber (order no.:
1-SG250). ABM75 (order no.: 1-ABM75) covering tape can be carefully
applied as the second layer.