15 Technical data
CAUTION! TNV-1 installation type. The
installation is type TNV-1, do not connect it
to SELV circuits.
CAUTION! In order to reduce the risk of
fire, only use UL Listed or CSA certified
cables with sections greater than or equal
to 0.14mm² (26AWG).
15.1 ULISSE EVO (UE)
15.1.1 General
Easy installation thanks to the self-centering
connector
Zero backlash
Quick configuration and setup
Dynamic positioning control system
Functions: Preset, Preset Tour (Patrol), Autoflip,
Autopan via Preset Tour
Maximum number of presets: 250
15.1.2 Mechanical
Constructed from aluminium and technopolymer
Epoxy-polyester powder painted, standard colours
grey-white (RAL9002) or black (RAL9005)
Horizontal rotation: 360°, continuous rotation
Vertical rotation: from -90° up to +90° (with ceiling
installation, from -40° up to +90°)
Horizontal speed (variable): from 0.1°/s up to 250°/s
Tilt speed (variable): from 0.1°/s up to 250°/s
Accuracy of preset positions: 0.05°
Cable glands: 2xM16 + 1xM20 + special gasket for
pre-wired Ethernet cables
Unit weight: 7.1kg (15.6lb) (7.4kg (16.3lb) with LED
illuminator)
Glass window
• Thick: 6mm (0.24in)
MNVCEVO_2203_EN
15.1.3 Electrical
Supply voltage/Current consumption:
• 24Vac ±20%, 5A, 50/60Hz
• 24Vdc ±10%, 5A
• PoE 90W compatible with standard IEEE802.3bt
CLASS 8 (LLDP protocol not supported), usable
with accessory PSINJ95CH1
• PoH 90W (backward compatibility mode usable
with accessory OHEP90INJ, PSINJ95CH1 or
OHEP90INJO)
Power consumption:
• 21W, PTZ camera stationary, heating switched off
(with the ECO-MODE function enabled, energy
saving function that is activated only when the
PTZ camera is stationary)
• 27W, PTZ camera stationary, heating switched off
(with the ECO-MODE function not enabled)
• 27W, PTZ camera moving, heating switched off
• 57W, peak at start-up, heating and de-icing
functions switched on
Power consumption with illuminator on:
• 34W, PTZ camera stationary, heating switched off
(with the ECO-MODE function enabled, energy
saving function that is activated only when the
PTZ camera is stationary)
• 40W, PTZ camera stationary, heating switched off
(with the ECO-MODE function not enabled)
• 40W, PTZ camera moving, heating switched off
• 70W, peak at start-up, heating and de-icing
functions switched on
Power supply cables section: from 0.75mm² (18AWG)
up to 2.5mm² (13AWG)
Cables signal section: from 0.14mm² (26AWG) up to
1mm² (17AWG)
Multipolar cable sheath diameter:
• Cable glands M16: from 4.5mm (0.2in) up to
10mm (0.4in)
• Cable glands M16 with reduction gasket : from
2mm (0.08in) up to 6mm (0.24in)
• Cable glands M20: from 8mm (0.3in) up to 13mm
(0.5in)
Alarm inputs: 2 (auto-powered from 12Vdc up to
18Vdc)
Relay outputs: 2 (1A, 30Vac/30Vdc max)
33