Fault
flashing red
System monitoring indicates faulty
operating state.
Charging plug cannot be removed
from the charging station.
LED info bar does not light up.
If you cannot rectify the error or fault, contact your local service partner.
Wechs el ein- auf z weis paltig
23
Cause
Residual current circuit breaker (RCCB)
or circuit breaker (CB) in the charging
station has tripped.
Error in the power supply to the
charging station (incorrect phase
sequence, missing phase, etc.).
Charging plug not interlocked.
Incorrect or faulty charging cable.
E.g. incorrect phase sequence, missing
phase / neutral, undervoltage.
Failure of the unlocking function.
No power supply to the charging
station.
Control fuse in the charging station has
tripped.
Notes on troubleshooting
Re-activate residual current circuit
breaker (RCCB) or circuit breaker (CB).
 See Chapter 7.3.2 on page 19.
Check the power supply.
Acknowledge the fault with multi-
function button.
Disconnect charging cable and plug in
again.
Acknowledge the fault with multi-
function button.
Disconnect charging cable and plug in
again.
Check charging cable and replace if
necessary.
Check the power supply.
 See Chapter 9.3 on page 24.
Unlock the charging plug manually.
 See Chapter 9.2 on page 24.
Check the power supply.
Re-activate control fuse.