Brink Renovent Excellent 180 Consignes D'installation page 75

Masquer les pouces Voir aussi pour Renovent Excellent 180:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electric connections accessories
11.5 Connection diagram preheater or postheater connection (only possible for Renovent Excellent Plus)
The preheater and postheater (postheater only possible for Plus version) are connected electrically to connector X14 and connector
also a temperature sensor that must be connected to no. 7 and no. 8 of the 9-pole connector. Please refer to the supplied mounting
instructions for more extensive information regarding installation of the postheater or the extra preheater.
Preheater
no. 2
D
E
no. 1
F
Ø >0.75mm
230 V
50 Hz
X12
A
A Renovent Excellent
B Print
C Heating coil 1000W max.
Maximum safety with
D
manual reset
LED maximum safety;
E
lights up when enabled
Cable to be connected
F
by installer
G
heater
Step
Description
Factory setting
no.
Preheater con-
12
nected
13
Heater
C
G
2
C1 brown
C2 blue
C3 green/yellow
C4 black
X12
B
IV
I =
To dwelling
II =
To atmosphere
III =
From dwelling
IV =
From atmosphere
Range
OFF = switched off
OFF
ON = switched on
0 = off
0
1 = preheater
2 = postheater
Renovent Excellent 180
Postheater (only possible for Plus version)
no. 2
F
no. 1
230 V
50 Hz
Ø >0.75mm
2
230 V
50 Hz
X14
A Renovent Excellent Plus
B Plus board
C Heating coil 1000W max.
D Temperature sensor
Maximum safety with
E
manual reset
LED maximum safety;
F
lights up when enabled
Cables to be connected by
G
installer
H
heater
Step no. Description
13
Heater
14
Temp. postheater
Chapter 11
D
E
C
G
H
C1 brown
C2 blue
C3 green/yellow
C4 black
C5 white
A
B
I
I =
To dwelling
II =
To atmosphere
III =
From dwelling
IV =
From atmosphere
Factory setting
Range
0 = off
0
1 = preheater
2 = postheater
21 °C
15°C - 30°C
31