3.1 Technical information

Supply voltage [V/Hz]
Protection degree
Dimensions (w x h x d) [mm]
Duct diameter [mm]
External diameter condensate discharge [mm]
Weight [kg]
Filter class
Fan setting (factory setting)
Ventilation capacity [m
3
/h]
Permissible resistance ducts system [Pa]
Rated power [W]
Rated current [A]
Max. Rated current [A]
Sound power Excellent 180
Ventilation capacity [m
3
/h]
Sound power
Static pressure [Pa]
level Lw (A)
Housing emission [dB(A)
Duct "from dwelling" [dB(A)]
Duct "to dwelling" [dB(A)]
In practice, the value may deviate 1 dB(A) as a result of measuring tolerances
6
50
7 - 15
13 - 14
0.12 - 0.14
0.44 - 0.46
Renovent Excellent 180

Version

Renovent Excellent 180
230/50
IP30
560 x 600 x 315
Ø 125
Ø 20
25
G3 (F6 optional)
1
2
75
100
21 - 35
36 - 62
20 - 22
28 - 34
0.19- 0.20
0.26 - 0.29
1.48
0.45 - 0.49
0.47 - 0.51
75
100
40
80
32
39
31
37
49
56
3
150
73 - 139
56 - 74
0.51 - 0.62
0.48 - 0.52
150
160
48
45.5
66