Installation

5.1 Installation general

Installing the appliance
1. Placing the appliance (§5.2)
2. Connecting the condensate discharge (§5.3)
3. Connecting the ducts (§5.4)
4. Electric connection:
Connecting the mains power, multiple switch and, if neces-
sary, the eBus connection (§5.5)
Installation must take place under:

5.2 Placing the appliance

The Renovent Excellent can directly be mounted to the wall
using the suspension brackets supplied for that purpose. For a
vibration-free result the appliance must be mounted to a solid
wall with a minimum mass of 200 kg/m
double panelling or extra studs are required in that case. On
addition, the following aspects must be taken into account.

5.3 Connecting the condensate discharge

The condensate discharge line for the Renovent Excellent
is fed through the lower panel. The condensate must be di-
scharged through a drainpipe.
The condensate discharge comes separately with the appli-
ance and the installer must screw
obtain a leakproof connection. Maximum torque is 10 Nm. This
condensate discharge connection has an external connection
diameter of 20 mm.
The condensate discharge line can be glued to it, if necessary
using a square bend. The installer can glue the condensate
discharge in the desired position in the lower part of the ap-
pliance. The drain must discharge under the water level in the
U-trap. Before connecting the condensate discharge to the ap-
pliance, pour water into the U- or S-trap to create an air seal.

5.4 Connecting ducts

vent condensation on the outside of the outdoor air supply duct
and the air exhaust duct from the Renovent Excellent, these
ducts must be provided with an external vapour barrier as far
as the appliance. If Brink synthetic (EPE) pipe is used here,
additional insulation is not necessary.
For optimum fan noise damping, it is recommended to use
Brink acoustic ducts with a length of 1 m between the ap-
pliance and the ducts from and to the dwelling.
2
. A gypsum block or
-
Renovent Excellent 180
dings
lings and residential buildings
sate discharge with air trap and pitch for condensate can
be made.
the front of the appliance and a free headroom of
1.8 m.
Glued connection;
Ø 20 mm
Pay attention to crosstalk and installation noise, also for incor-
porated ducts. Design the duct with separate branches to the
diffusers to prevent crosstalk. If necessary, the supply ducts
must be insulated, for instance when they are installed outside
the insulated envelope.
Preferably use Brink incorporated ducts. These ducts have
been developed with a view to a low duct resistance.
A duct diameter of 125 mm is required for the Renovent Excel-
lent 180.
Chapter 5
Screw connection
A
A = Minimum height > 60 mm
11
-
-
-