rectly whenever the solution required is not provided.
The inspection/maintenance operations to be routinely sche-
duled in the "complete automation maintenance handbook" are:
INTERVENTION TYPE
cleaning of external surfaces
checking of screw tightening
checking of release mechanism operation
greasing of articulated joint
WARNING The use of spare parts not indicated by DEA Sy-
stem and/or incorrect re-assembly can create risk to people,
animals and property and also damage the product. For this
reason, always use only the parts indicated by DEA System
and scrupulously follow all assembly instructions.

4.6. Training

After installation and setting, the correct operation of the com-
plete automation must be carefully illustrated to the final user.
ANGOLO gate operator requires careful instruction on the
release mechanism (see "Enclosures") and on the specific main-
tenance schedule (see Point 4.5.6.).
WARNING Awareness of the operation of ANGOLO key-
release mechanism (see F9 Page 48) is essential for all users
of the automatism because failure to use the device quickly
during emergencies can jeopardise people, animals and
property. Enclosure I to these instructions, which the installer
is required to deliver to the end user, illustrates this operation
and can be detached.

4.7. Inappropriate use

Chapter "4.4 Appropriate conditions of use" describes the
conditions for which the product has been designed and tested.
The product must never be used for other purposes.
WARNING Using of the product under unusual conditions
not foreseen by the manufacturer can create situations of dan-
ger, and for this reason all the conditions prescribed in these
instructions must be respected.
WARNING Under no circumstances must the product be
used in explosive atmospheres or surroundings that may prove
corrosive and damage parts of the product.
5 WIRING AND CONTROL
BOARD PROGRAMMING
5.1
Wiring and terminal board connections
WARNING To ensure an appropriate level of electrical safety
always keep the 230V power supply cables apart (minimum
4mm in the open or 1 mm through insulation) from low volta-
ge cables (motors power supply, controls, electric locks, aerial
and auxiliary circuits power supply), and fasten the latter with
appropriate clamps near the terminal boards.
WARNING Install the control board according to the instruc-
tions given at page 45. Drill only the holes foreseen by the
manufacturer to allow for wires passage, and use the specified
clamps. Failure to comply with these instructions may jeopar-
dise the level of electrical safety.
Connect to the power supply 230 V a.c .± 10% 50 Hz throu-
gh a multi pole switch or a different device that can ensure multi
pole disconnection from the power supply, with a contact ope-
ning of 3 mm. Use a cable with a minimum section of 3 x 1,5
mm² (e.g. a H07RN-F type). Ake all connections to the terminal
board and remember to short-circuit, whenever necessary, all
unused inputs. (See table 1 terminal board connection and
page 43 basic and complete wiring diagram)
Operating instructions and warnings
PERIODICITY
1-2
6 months
LC/SCA
3-4
6 months
ELETTR
6 months
5-6
LAMP
1 year
M2
7-8
M1
9-10
11
SIC1
12
SIC2
13
FOTOC
14
+24VSIC
15
+24VAUX
16
COM
17
FCC2
18
FCC1
19
FCA2
20
FCA1
21
START
22
PEDON
23
STOP
24
COM
25
26
27-28
24VBatt
29-30
24 V
Table 1 "Terminal board connection"
Free contact max. capacity 5 A : this contact
can be used to control an open gate warning
light (P27=0) or a courtesy lamp (P27≠0)
Electric lock output art. 110 12 V
Flashing light output 24Vdc max 15W (the in-
termittent output does not demand the use of
a flashing light card)
Motor 2 output
Motor 1 output
N.C. leaf nr. 1 safety device input. In case of
activation it reverses the movement (P18=0) or
it stops (P18=1). If unused, short circuit to the
terminal n°16
N.C. leaf nr. 2 safety device input. In case of
activation it reverses the movement (P18=0) or
it stops (P18=1). If unused, short circuit to the
terminal n°16
N.C.
Photocell input. In case of activation
it reverses the movement only while closing
(P26=0) or it reverses the movement while
closing and stops while opening (P26=1). If
unused, short circuit to the terminal n°16
+24V
power supply output for controlled
safety devices. To be used as power supply
of photocell transmitters (in all cases) and of
safety devices when testing these latter before
each operation
+24V
power supply output for auxiliary
circuits and uncontrolled safety devices To be
used as power supply of any auxiliary devices,
photocell receivers (in all cases), and of safety
devices when testing these latter before each
operation
Common safety devices
N.C. motor nr. 2 closing limit switch input. If
unused, it may remain disconnected
N.C. motor nr. 1 closing limit switch input. If
unused, it may remain disconnected
N.C. motor nr. 2 opening limit switch input. If
unused, it may remain disconnected
N.C. motor nr. 1 opening limit switch input. If
unused, it may remain disconnected
N.O. open input. If activated, it opens or closes
both motors. It can work in "reversal" mode
(P25=0) or "step-by-step" mode (P25=1)
N.O. pedestrian opening input. If activated, it
opens motor nr. 1 only.
N.O. stop input. If activated, it stops the mo-
vement of both motors during any operation. If
unused, short circuit to the terminal n°24.
Common inputs
Aerial signal input
Aerial ground input
24 V
battery power supply input (Follow
carefully polarity indications)
24 V
transformer power supply input
A N G O L O
15VA
13