JOB HOURS
RESET? >
Press > to reset hours to zero. NOTE: Mien in
Humidistat mode, the unit will display HUMIDISTAT on
the top line during normal operation rather than JOB
HOURS.
LIFE HOURS
00 HRS
Shows total unit operating hours. Value cannot be
modified.
INLET
OUTLET
0
00° 00
10 0 0° 00%
Shows current temperature and RH of inlet and outlet
The HygroTrac system uses these values to calculate
grain depression_
HUMIDISTAT MODE
ON/OFF >
ON mode. unit will maintain the hunnidistat setpoint
In
(see below). Press to toggle between ON and OFF.
NOTE: When in Humidistat mode, the unit will display
HUM IDISTAT on the top line during normal operation
rather than JOB HOURS.
HUMIDISTAT
SETPOINT 00%>
Sets humidity level when unit is in Humidistat Mode (see
above). Press > to change RH value at 5% increments.
Settings cycle upward through 90%RH and start again at
30°/0RH.
TEMP UNITS
F°>
Shows current temperature scale. Press
Fahrenheit or Centigrade scale.
LANGUAGE
ENGLISH >
Shows current display panel language. Press
select Spanish. German, French or English.
COIL TEMP
00°F
Displays the cold (evaporator) coil temperature.
141 Kirrierkamack Rd. Park Ridge, NJ 07656 Tel
Shows built-in wireless transmitter number. The
HygroTrac system uses this to uniquely identify your i-
Series unit. NOTE: For convenience, this same number
is shown on the barcode label affixed to the control
panel.
Press to cycle through the following values:
TYPE. SENSOR REVISION,
A Dri-Eaz service technician may ask you for these
values when diagnosing a problem.
Shows compressor current draw in amps.
Error messages
If
the i-Series onboard diagnostics discover a problem.
the unit will display an error message. If the unit is used
with the HygroTrac system, it will also transmit most
error messages to the user's HygroTrac webs ite. See
"System Status and Data Messages' and "Error
Messages." p. 8. for a summary of messages.
At the end of the job
As with all dehumidifiers, once the drying job is
_
completed. it is important to make sure the unit is
a••••
completely purged of water before moving it. To ensure
that all water has drained into the pump, follow these
9
steps:
1. Turn the unit off and allow the plugged in dehumidifier
to rest for 10 minutes.
2. Press the
operating. tip the unit back approximately 45
the unit in place until the purge cycle is complete. This
allows any water remaining on the coils to drain down
into the pump.
3. Return the unit to the upright position and press
PURGE
to select
purge cycle is complete, unplug the unit and remove it
promptly from the job.
Before transporting. be sure to remove the external drain
hose. drain it carefully, and return it to the pocket
provided on the back of the unit.
to

MAINTENANCE

Before each use
Inspect the electrical cord for damage.
fraying, cuts. etc. Do not use the unit if you find any
damage. Call Dri-Eaz for the nearest Service Center at
800-932-3030.
Air Marketing Group
201-782-1782 Fax. 201-782-1783 Web www amgair corn Email: info@amgair corn
SENSOR ID >
00000000
and
COMPRSSR CURRENT
0.0 A
PURGE
button and while the purge pump is
one more time to empty the pump. Once the
WARNING! ELECTRIC SHOCK HAZARD.
the dehumidifier before performing any
maintenance.
SENSOR
SENSOR CONF REV.
.
' and hold
Unplug
Look for