Rs485 Communication Setup [Rs485 Setup]; Selection Of Camera Unit Number [Unit Number]; Selection Of Data Baud Rate [Baud Rate]; Selection Of Data Bit [Data Bit] - Panasonic WV-CLR930 Mode D'emploi

Caméra de surveillance couleur
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

RS485 Communication Setup [RS485 SETUP]

The necessary setups to use the RS485 communication function are performed.
"COMMUNICATION" is selected through the top screen and the "RS485 SETUP" screen is
called.
Refer to pages 24 and 25 for how to call up the screen.
**RS485
UNIT NUMBER
BAUD RATE
DATA BIT
PARITY CHECK
STOP BIT
XON/XOFF
WAIT TIME
ALARM DATA
DELAY TIME
RET TOP END

Selection of camera unit number [UNIT NUMBER]

The unit number (1-96) of the camera that is controlled via the RS485 communication interface
is selected. (Default setting: 1)

Selection of data baud rate [BAUD RATE]

The data baud rate is selectable from the following:
2400/4800/9600/19200 (default) bps

Selection of data bit [DATA BIT]

The communication data length is selectable from the following:
7/8 (default) bits

Selection of parity check [PARITY CHECK]

The transmission error check method at communication is selectable from the following:
NONE (default): No parity check
EVEN: Even parity
ODD: Odd parity

Selection of stop bit [STOP BIT]

The stop bit is selectable from the following:
1 bit (default)/2 bits
SETUP**
1
19200
8
NONE
1
NOT USE
OFF
AUTO2
---
53

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wv-clr934

Table des Matières