4. Tighten the jam nut (Figure 36), ensuring there is slight
tension on the cable.
5. If the traction cable is properly adjusted but a problem
remains, contact an Authorized Service Dealer.
Checking and Adjusting the
Auger/Impeller Cable
Service Interval: After the first 2 hours—Inspect the
auger/impeller cable and adjust it if
necessary.
Yearly—Inspect the auger/impeller cable
and adjust or replace it if necessary.
1. Loosen the jam nut.
2. Engage the auger/impeller lever and hold it in place
(Figure 37).
3. Loosen or tighten the turnbuckle to adjust the spring
length to 2.75 inches (7 cm) (Figure 38).
g019047
1. Jam nut
2. Turnbuckle
4. Tighten the jam nut (Figure 38), ensuring there is slight
tension on the cable.
5. If the auger/impeller cable is properly adjusted but
a problem remains, contact an Authorized Service
Dealer.
22
Figure 37
4
3
Figure 38
3. Spring
4. 2.75 inches (7 cm)
2
1