cap.02 EU65is 6500is (Eu).qxd 07.12.17 4:25 PM ページ2-15
E-00
(Starter motor failure)
Check the battery (P. 5-1).
Check the ignition pulse generator air gap (P. 11-4).
Check the ignition pulse generator (P. 11-4).
Check the harness connecting the ignition pulse generator and
GCU for open or short circuit and for proper connection.
Wire harness check points
ENGINE WIRE
HARNESS
C22
Bu
C21
IGNITION
Bl
PULSE
GENERATOR
GND5
2-15
Good
Normal
Normal
CONTROL WIRE HARNESS
Y/Bu
Y/Bu
G
G
Viewed from terminal side
Normal
To P. 2-16
Abnormal
Abnormal
Abnormal
Abnormal
GCU
Y: YELLOW
Bu: BLUE
G: GREEN
Replace or recharge the battery
(P. 5-1 and 2).
Adjust
the
ignition
pulse
generator air gap (P. 11-4).
Replace
the
ignition
pulse
generator (P. 11-3).
Replace
or
repair
the
wire
harness.