Code table
Code
No.
Designation
C0417
Configuration of
v
starttec status
messages (1)
1 Bit 0
2 Bit 1
3 Bit 2
4 Bit 3
5 Bit 4
6 Bit 5
7 Bit 6
8 Bit 7
9 Bit 8
10 Bit 9
11 Bit 10
12 Bit 11
13 Bit 12
14 Bit 13
15 Bit 14
16 Bit 15
C0418
Configuration of
v
starttec status
messages (2)
1 Bit 0
... ...
16 Bit 15
C0423
Switch−on delay
of brake
C0424
Switch−off delay
of brake
126
Setting options
Lenze
Selection
Output of internal digital signals to bus
1
Reserved
2
Reserved
3
Status of motor 1
4
Status of motor 2
5
Status of brake
6
Error in power section
7
Reserved
8
starttec released/inhibited
9
11|10|9|8 Device status
10
0011 Operation inhibited
11
0110 Operation released
12
1000 Active fault
13
Overtemperature" warning
14
Reserved
15
Reserved
16
Ready for operation
For possible internal digital signals
see C0415
Output of internal digital signals to bus
255
Not assigned
...
255
Not assigned
Internal digital signals same as
C0415
0.00
0.00
0.00
0.00
EDK71MMXXX−010 DE/EN/FR 5.0
20.00 Only affects brake output
{0.01 s}
{0.01 s}
20.00
IMPORTANT
The assignment is mapped
to
starttec status word 1
l
(C0150)
l
FIF output word 1
(FIF−OUT.W1)
Output word 1 in CAN
l
object 1 (CAN−OUT1.W1)
The assignment is mapped
to
l
Drive controller status
word 2 (C0151)
FIF output word 2
l
(FIF−OUT.W2)
l
Output word 1 in CAN
object 2 (CAN−OUT2.W1)
X1/B1, B2