Control of starttec with PROFIBUS−DP FIF module
The control of starttec via PROFIBUS−DP FIF module is possible via control word FIF−CTRL1 and status
word FIF−STAT1.
The following bit assignment applies:
Bit
Assignment of control word FIF−CTRL1
0
S1
1
S2
2
Reserved
3
Reserved
4
Reserved
5
Reserved
6
Reserved
7
Reserved
8
Reserved
9
Controller inhibit (FIF−CTRL1−CINH)
0 = controller released
1 = controller inhibited
10
External fault (FIF−CTRL1−TRIP−SET)
11
Reset fault (FIF−CTRL1−TRIP−RESET)
0 = a bit change causes TRIP reset
12
Reserved
13
Reserved
14
Reserved
15
Reserved
L
Electrical installation
Connection of bus function module
Assignment of status word FIF−STAT1
Reserved
Pulse inhibit (DCTRL1−IMP)
0 = power outputs released
1 = power outputs inhibited
Reserved
Reserved
Reserved
Reserved
Fixed 1
Controller inhibit (DCTRL1−CINH)
0 = controller released
1 = controller inhibited
Device status (DCTRL1−STAT*1 ... DCTRL1−STAT*6)
0001 = switch−on inhibit
0011 = operation inhibited
0110 = operation released
1000 = fault active
Reserved
Reserved
Reserved
Ready for operation (DCTRL1−RDY)
0 = not ready for operation (fault)
1 = ready for operation (no fault)