Lenze starttec type1 Instructions De Montage page 69

Démarreur moteur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Quick commissioning
,
1
2
3/N/PE AC 100 ... 550 V
45 ... 65 Hz
L1
L2
L3
N
PE
3
X1
L1 L2 L3
X1
1U
1V
1W
M
3~
OFF
0
4
3.0 A
}
2.4 Nm
21 lb-in
5
6
7
?
?
Read safety instructions
Assemble starttec
Establish minimum wiring
X1
X3
BN
20 28
20
X3
2U
2V
2W
B1 B2
T1 T2
Set the rated motor current with stepping switch for I
(
Position 0" (OFF) = no I
Close starttec
7. Ensure that terminal X3/28 = LOW
8. Switch in mains voltage
9. Switch on 24−VDC supply
Start the drive
1. Release starttec:
– X3/28 = HIGH
2. Release brake, if necessary:
– X3/E3 = HIGH
3. Start motor 1
– X3/E1 = HIGH
Faults during commissioning or during operation?
(+18 VDC - 0 % ... +30 VDC + 0 %,
E1
E2 E3 E4 E5
20
7
7
A1 A2 A3 A4
X3
A+ A-
2
t monitoring
^ 71
^ 81
+24 V DC
200 mA ... 1.5 A)
+
-
^ 84
7 59 59
7 7
GND
2
t monitoring
^ 96
^ 98
^ 97
^ 128

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E71mm402 x a 2a 22 série

Table des Matières