Objets de base

Group
Property
object_identifier
object_type
event_state
object_name
out_of_service
polarity
present_value
priority_array
reliability
relinquish_default
active_text
inactive_text
status_flags
in_alarm
fault
overridden
out_of_service boolean
object_identifier
object_type
event_state
object_name
out_of_service
polarity
present_value
priority_array
reliability
relinquish_default
status_flags
in_alarm
fault
overridden
out_of_service boolean
Notes
1 --
'R' indicates that this property is required by ASHRAE Standard 135
'O' indicates that the property is optional in ASHRAE Standard 135
2 --
'C' indicates the property is hard-coded as a constant
'N' indicates the property is stored in non-volatile memory
'R' indicate the property is computed constantly and stored in RAM.
Storage
Data Type
1
Type
Required
R
enumerated
R
enumerated
R
character string
R
boolean
R
enumerated
R
enumerated
R
R
enumerated
0
R
character string
O
character string
O
boolean
R
boolean
R
boolean
R
R
R
enumerated
R
enumerated
R
character string
R
boolean
R
enumerated
R
enumerated
R
R
enumerated
0
R
boolean
R
boolean
R
boolean
R
R
BACnet
2
Writeable?
46344 (or 0xB508) for Relay #1 up to
C
N
46347 (or 0xB50B) for Relay #4
C
N
binary_output (4)
C
N
normal (0)
"device_object_name .relX", where
device_object_name is programmed on the
LUI and defaults to "VA301C:1" and X is
N
N
relay number (1 to 4). Thus the default
object_name for Relay #4 will be
"VA301C:1.rel4"
C
N
FALSE
C
N
always Normal (0)
True state of the relays. These take the
Only
value of the highest-priority BACnet
R
Rly1&2. Not
command. If no BACnet command, this
Rly 3or4.
takes the value of the associated event.
R
N
last value written
C
N
no_fault_detected (0)
C
N
not meaningful
C
N
"ON"
C
N
"OFF"
C
N
always "false" (0)
C
N
always "false" (0)
R
N
always "false" (0)
R
N
always "false" (0)
C
N
46360 (or 0xB518)
C
N
binary_output (4)
C
N
normal (0)
"device_object_name .buzz", where
device_object_name is programmed on the
N
N
LUI and defaults to "VA301C:1" . Thus the
default object_name will be
"VA301C:1.buzz"
C
N
FALSE
C
N
always Normal (0)
True state of the buzzer. This takes the
value of the highest-priority BACnet
R
Y
command. If no BACnet command, this
takes the value of the associated event.
R
N
last value written
C
N
no_fault_detected (0)
C
N
not meaningful
C
N
always "false" (0)
C
N
always "false" (0)
C
N
always "false" (0)
C
N
always "false" (0)
185
Value

Publicité

Chapitres

Table des Matières
loading

Table des Matières