core probe is inserted, the core temperature can be viewed at any time: when
read by the probe in green for 5 seconds.
beginning of the cycle in green for 5 seconds. After 90' (maximum time admitted for reducing product temperature) the chilling cycle
ends and holding period begins:
remains on and the display indicates the chamber temperature in red.
Attention: the cycle can be interrupted at any time by pressing
beginning.
7.7.3 – SETTING A TEMPERATURE CONTROLLED SOFT CHILLING CYCLE
With the appliance on STANDBY press
seconds the display will show
edit this value: press
chilling).
The
icon will now remain on while the
value: press
again to confirm the setting and view
icon will now remain on while the
to confirm the setting.
Press
(START) at any time to begin the cycle.
Attention: when selecting the cycle, if values different from the recommended ones are set they will not be saved and will be active only
until another cycle is selected or the machine is turned off.
7.7.4 – SETTING A TIME CONTROLLED SOFT CHILLING CYCLE
With the appliance on STANDBY press
the display will show
-5° C
in red (recommended chamber temperature during chilling).
value: press
again to confirm the setting and view
on and the
icon will continue to flash.
setting and view
+2° C
(recommended chamber temperature for the holding period). The
icons will flash. Use the
Press
(START) at any time to begin the cycle.
Attention: when selecting the cycle, if values different from the recommended ones are set they will not be saved and will be active only
until another cycle is selected or the machine is turned off.
7.8 – HARD CHILLING
7.8.1 – SELECTING A TEMPERATURE CONTROLLED HARD CHILLING CYCLE
Load the machine suitably with the food to be chilled, place the core probe into the food and close the door.
With the appliance on STANDBY press
and
icons will flash. After three seconds the display will show
chilling). Press
(START) to begin the cycle. During
display shows the core temperature in red.
show the temperature read by the probe in green for 5 seconds. In the same way, when
minutes from the beginning of the cycle in green for 5 seconds. When the core temperature reaches set-point for the
first part of the chilling cycle ends and the second one begins: on the display the
When the core temperature reaches set-point the whole chilling cycle ends and the holding period begins: the two icons
remain on, the
icon flashes for a few seconds and the buzzer sounds. The
temperature in red.
Attention: if the entire chilling cycle (first
flash to indicate that the time limit has been exceeded.
temperature.
The cycle can be interrupted at any time by pressing
beginning.
BCB_03-05-10-15 Rev.02
In the same way, when
illuminates, the icon
: the display will show the word
-5° C
in red (recommended chamber temperature during chilling).
again to confirm the setting and view
and
icons will flash. Use the
: the display will show the word
Use the
and
buttons to edit this value: press
twice: the display will first show the word
The chamber temperature can be viewed at any time: press
HARD
stage plus second stage) exceeds 90' (admitted time limit) the
is pressed, the display will show the minutes from the
flashes for a few seconds and the buzzer sounds. After that the
(STOP): pressing
"SOFT"
+3° C
(recommended core temperature to be reached to complete
icon will continue to flash.
+2° C
(recommended chamber temperature for the holding period). The
and
"SOFT"
90'
(maximum time admitted to complete chilling). The
and
buttons to edit this value: press
again to confirm the setting.
-20°C
in red (recommended chamber temperature during
HARD
chilling the
and
icon remains on and the display shows the chamber
Press
to view the total time taken to chill the product to the required
(STOP): pressing
is pressed the display will show the temperature
(START) again starts the cycle from the
and
and
will flash.
Use the
Use the
and
buttons to edit this value: press
and
and
will flash. After three seconds
Use the
and
icon will remain on and the
"SOFT"
then the word
"HARD"
icons flash while
is pressed the display will show the
icon remains on and
(START) again will re-start the cycle from the
icon
After three
and
buttons to
buttons to edit this
again
buttons to edit this
icon will remain
again to confirm the
and
and the
,
HARD
remains on. The
, the display will
HARD
cycle, the
continues to flash.
and
icon continues to
pag. 62