Electrical Specification - Renishaw TS20 Guide D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1-10
The TS20 probe is designed to be used wIth a load resistor.
Minimum load resistor at 30 V
Maximum supply voltage 30 V
Minimum supply voltage 9 V
Cable
Four core 7/0,2 polyurethane insulated
and screened cable.
Probe circuit - red and blue cores,
(yellow and green are not used).
Electrical characteristics at 20° C (68° F)
Voltage drop across output leads

ELECTRICAL SPECIFICATION

TS20 with signal conditioning module (SCM)
Stand-by current
(probe deflected)
(probe seated)
Load current 25mA
5mA
2mA
Output pulse length when
probe deflects (trigger)
1K2 Ohms
Maximum current 25 mA - probe seated
Minimum current 2 mA - probe seated
The load resistor is connected in either
positive or negative lead (see opposite).
It can be any value that does not cause the
circuit to exceed the max/min current ratings.
The probe is protected against reverse voltage
within the specified ratings.
Minimum
Typical
320 µA
4.5 V
3.5 V
2.8 V
20.0 mS
Maximum
500 µA
5.2 V
3.9 V
3.1 V