Installation Example For Aquafix Installation Parts; Assembly - Franke AQUA401 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

10. Installation example for AQUAFIX installation parts

11. Assembly

Warning!
• Operate the product only with safety extra low voltage (SELV). The components
must not be earthed.
• Place the power supply (not part of the delivery scope, see accessories, Chapter
20) outside the wet area in a separate room.
• Protect the power supply with a residual current circuit breaker (RCD).
• Lay the system line (to be provided by the customer) in the empty pipe (to be
provided by the customer) from the power supply to the fittings and loop through.
Failure to observe this instruction can result in death or material damage due to
electric shock or fire, for example.
Important!
Prior to the assembly process, flush the pipework in accordance with DIN 1988.
11.1 Release the screws.
11.2 Remove the wall protection.
11.3 Close the water volume regulator with a screwdriver having a blade width of 8 mm.
Screw the water volume regulator as far as it will go.
Caution!
Do not remove the locking ring.
11.4 Remove the flush stopper.
11.5 Screw in the solenoid valve cartridge.
11.6 Use the flush stopper as a spanner to screw down the solenoid valve cartridge.
Important!
Take care when tightening the solenoid valve cartridge.
Keep the flush stoppers in the wall mounting box in order to remove the solenoid
valve cartridge.
11.7 Open the water volume regulator (water flow must end automatically after a brief
flush time).
Screw the water volume regulator as far as it will go.
Caution!
Do not remove the locking ring.
11.8 Remove the supporting frame from the cover plate by releasing the grub screw.
11.9 Screw on the supporting frame horizontally.
11.10 Remove the earth line (a).
- 6 -

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

7612982074776

Table des Matières