7.

Scope of Delivery

Basic installation kit
Quantity
1
1
Complete installation kit
Quantity
1
1
1
1
1
8.

Dimensions

9.

Installation Example

10. Installation and Assembly, Basic Installation Kit

Warning!
The power supply (not included in the scope of delivery, see accessories,
Chapter
19) must be set up outside of the wet area, in a separate room.
Failure to observe can mean risk of death or material damage, e. g. from electric
shock or fire.
The system line (not included in the scope of delivery) for connecting the power
supply to the fittings must be installed in a conduit (to be supplied by customer) and
looped through.
10.1 Mount the in-wall installation box horizontally into the recess provided for this
purpose and fasten.
Caution!
While turning the union nuts (a), use an open-end spanner to hold the water volume
regulators (b) in place.
10.2 Connect to the water supply.