8.

Dimensions

9.

Installation example

10. Assembly

Warning!
Only operate the fitting with non-return valves and the specified filters.
Failure to observe this instruction can result in an increased germ load in the
drinking water and thus pose a health or mortality risk.
Important!
Prior to the assembly process, flush the pipework in accordance with DIN 1988.
10.1 Remove the wall protection.
10.2 Use an Allen key to close the water volume regulators.
a: closed
b: open
10.3 Open the locking screws (c) of the water quantity regulators (d).
Important!
Note the installation position of the filters (e).
10.4 Insert the filters (e).
10.5 Screw in the locking screws (c).
Caution!
Use an open-ended wrench to hold the water quantity regulators (d) in position while
turning the cap nuts (f).
tightening torque: 1 Nm
10.6 Remove the T-type flush connector (g) and any seals that are present.
10.7 Install the fitting (h) with new seals.
10.8 Open the water volume controls (see
10.9 Check the water connections for leaks.
10.10 Install the frame (i) in a horizontal position.
10.11 Shorten the spacer sleeves (k) to fit the distance from the front edge of the wall unit
to the front edge of the tiles, as required.
Simplified drawing without fitting
10.12 Release the screw (n) with its disk.
10.13 Remove the temperature selector (m) and the stop ring (l).
10.14 Pull the protective foil off the cover plate.
10.15 Seal the cover plate, e.g. with Chromol (not part of the delivery scope, see Acces-
sories
Chapter
22).
Work step 10.2
).
- 6 -