3.2 INSTALLATION
The ultrasonic transmitter or sensor may be installed through the tank top via a standard
G 2" (NPT) fitting or equivalent tapped flange according to the type of level transmitter.
Steps for successful installation:
When securing the transmitter or sensor to the fitting, only tighten by
-
hand!
Be careful not to overtighten the transmitter in the fitting.
-

3.2.1 Panel version installation

For installation and insertion of the panel version follow the instructions on the enclosed
delivery film, the self-adhesive pattern to cut the panel and as follows:
1. Put gasket "2" on the cover 1 and place the complete unit in the cut-away panel.
2. Screw the spacer bolts "3" onto the panel fixing screws "4".
3. Insert the cable clips "8", to secure the various cables (power supply, outputs, sensor) of
the transmitter, onto the plate "5".
4. Fasten the plate "5" with the screws "7" onto the bolts "3", tightening the locking
washers "6".
3.2.2 Wall-mounted version installation
The level transmitter in a wall-mounted version has 4 fixing holes at the corners of the en-