General Information on Solution 3.5 (EB00053)

2.1 Appliance performance

Fuel type
Recommended heating area
Firebox volume
Maximum burn time
Maximum heat output (dry cordwood)
Overall heat output rate (min. to max.)
Average overall efficiency
Optimum efficiency
Average particulate emissions rate
Average CO
[*]
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss
factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the
manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a
power failure.
(1)
Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn
time and maximum heat output.
(2)
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft
Other performances are based on a fuel load prescribed by the standard. The specified loading density varies
between 7 lb/ft
(3)
As measured per CSA B415.1-10 stack loss method.
(4)
Higher Heating Value of the fuel.
(5)
Lower Heating Value of the fuel.
(6)
Optimum overall efficiency at a specific burn rate (LHV).
(7)
This appliance is officially tested and certified by an independent agency.
(8)
Carbon monoxide.
Solution 3.5 Installation and Operation Manual
Stove Builder International Inc. | 44826 | Rev: May 31 2019 2:49PM | Uncontrolled Copy
(1)
[*]
[*]
(2)
(2)(3)
(3)
- Dry cordwood
(2)(6)
(7)
(8)
3
3
and 12 lb/ft
. The moisture content is between 19% and 25%.
Dry cordwood
2
1,000 to 2,700 ft
(93 to 223 m
3
3
3.7 ft
(0.105 m
)
10 h
100,000 BTU/h (29.3 kW)
18,100 BTU/h to 51,100 BTU/h
(5.3 kW to 15.0 kW)
71% (HHV
(4)
)
77% (LHV
77.2%
1.32 g/h (EPA / CSA B415.1-10)
78 g/h
(7 OF 57)
2
)
(5)
)
3
3
and 20 lb/ft
.
7