1 - INSTALLATION MANUAL SERIES 3.5 ENGLISH
PART B - INSTALLATION

7. Safety Information and Standards

• The information given on the certification label affixed to the appliance always overrides the
information published, in any other media (owner's manual, catalogues, flyers, magazines and web
sites).
• Mixing of appliance components from different sources or modifying components may result in
hazardous condtions. Where any such changes are planned, Stove Builder International Inc. Should
be contacted in advance.
• Any modification of the appliance that has not been approved in writing by the testing authority
violates CSA B365 (Canada), and ANSI NFPA 211 (USA).
• DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION
DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATION.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
• Connect this stove only to a listed factory-built chimney for use with solid fuel or to a lined masonry
chimney conforming to national and local building codes.
• If required, a supply of combustion air shall be provided to the room.
7.1

Mobile Home

• May be installed in a mobile home. The installation requires a fresh air kit, sold separately.
• WARNING : DO NOT INSTALL IN SLEEPING ROOM.
• THE STOVE MUST BE ATTACHED TO THE STRUCTURE OF THE MOBILE HOME.
• CAUTION : THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, CEILING
AND ROOF MUST BE MAINTAINED.
7.2

Regulations Covering Stove Installation

When installed and operated as described in these instructions, this wood stove is suitable for
use as a freestanding heater in residential installations.
In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment
and the CSA C22.1 Canadian National Electrical Code are to be followed in the absence of local
code requirements. In the USA, the ANSI NFPA 211 Standard for Chimneys, Fireplaces, Vents
and Solid Fuel-Burning Appliances and the ANSI NFPA 70 National Electrical Code are to be
followed in the absence of local code requirements.
This stove must be connected to a chimney complying with the requirements for Type HT
chimneys in the Standard for Factory-Built Chimneys for Residential Type and Building Heating
Appliances, UL 103 and ULC S629 or to a code-approved masonry chimney with a flue liner.
7.3

Location of the Certification Label

Since the information given on the certification label affixed to the appliance always overrides
the information published, in any other media (owner's manual, catalogues, flyers, magazines
and web sites) it is important to refer to it in order to have a safe and compliant installation.