IRING DIAGRAM OF THE PRINTED IRING BOARD
SCHMA ELECTRIQUE DU CIRCUIT IMPRIM
Remote controller (RAR-2P2)
Tlcommande (RAR-2P2)
1 S E G 1 5
2
S E G 0
3
S E G 1
4
S E G 2
5
S E G 3
6
S E G 4
7
S E G 5
8
S E G 6
9
S E G 7
1 0
C OM 3
1 1
C OM 2
1 2
C OM 1
1 3
C OM 0
1 4 S E G 1 4
1 5 S E G 1 3
1 6
S E G 1 2
1 7 S E G 1 1
1 8 S E G 1 0
1 9
S E G 9
2 0
S E G 8
D 3
R B 4 2 5 D
(1 / 2 )
+
C 8
−
5 0 v / 1 u
Key matrix table
output
D0
D1
input
Door open
Start/Stop
Operation selection
P10
Door shat
Start/Stop
Dry
Door open
On timer
Hour up
P11
Door shat
Room temperature up
Door open
Off timer
P12
Door shat
Sleep
Door open
P13
Door shat
S E G 2 0
4 0
S E G 1 9
3 9
S E G 1 8
3 8
S E G 1 7
3 7
S E G 1 6
3 6
S E G 2 1
3 5
3 4
S E G 2 4
3 3
S E G 2 5
S E G 2 6
3 2
S E G 2 7
3 1
L C D 1
S E G 2 8
3 0
N . C
2 9
N . C
2 8
N . C
2 7
6 4 6 3 6 2 6 1 6 0 5 9
N . C
2 6
2 5
N . C
2 4
N . C
6 5 S E G 2 0
N . C
2 3
6 6 S E G 2 1
N . C
2 2
6 7 S E G 2 2
N . C
2 1
6 8 S E G 2 3
6 9 S E G 2 4
7 0 S E G 2 5
7 1 S E G 2 6
7 2 S E G 2 7
7 3 S E G 2 8
7 4 S E G 2 9
K 1
K 6
K 1 3 , K 1 4
D 0
7 5 S E G 3 0
7 6 S E G 3 1
7 7 S E G 3 2
7 8 S E G 3 3
K 2 , K 3
K 7 , K 8
K 1 5 , K 1 6
D 1
7 9 S E G 3 4
8 0
S E G 3 5
K 4
K 9 , K 1 0
K 1 7
D 2
1
K 5
K 1 1 , K 1 2
K 1 8
D 3
R 1
1 0 0 k
D2
D3
Fan speed selection
Hour down
Dry ¥ present time
Room temperature down
Reservation
Cancel
5 8
5 7 5 6
5 5 5 4 5 3 5 2 5 1 5 0 4 9 4 8 4 7 4 6 4 5 4 4 4 3 4 2 4 1
V L C 1
V L C 2
V L C 3
X C I N
X C
I C 1
(M 3 4 5 5 0 M 6 A− * * * F P)
A X − 5 2 P 2
X
X I N
R E S E T
C A R R
2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4
SW 1
SW− 1 8 7 − 2 P
Tableau matriciel des touches:
Sortie
D0
Ente
Volet ouvert
Marche/arrt
P10
Volet ferm
Marche/arrt
Volet ouvert
Programmateur de mise en marche
P11
Volet ferm
Volet ouvert
Programmateur d'arrt
P12
Volet ferm
Veille
Volet ouvert
P13
Volet ferm
P 3 0
4 0
P 3 1
3 9
3 8
3 7
3 6
3 5
O U T
3 4
V D D
3 3
V S S
3 2
O U T
3 1
3 0
2 9
2 8
P 2 3
2 7
P 2 2
2 6
P 2 1
2 5
D 1 , D 2
E L − 1 L 7
D 3
R B 4 2 5 D
D 1
D 2
(1 / 2 )
R 6
R 7
R 8
R 9
R 3
R 1 0
R 2
1 0 0 k
1 . 2 M
1 0 0 k
R 6 − R 9
2 . 4 (1 / 8 W)
R 5
Q 1
3 3 0
2 S C 3 4 4 3
k 1 9
R 4
o r 2 S C 2 9 8 2
J P
1 0 0 k
C 1
C 2
3 3 4
2 2 0 p
D1
Choix du mode
Slection de la vitesse de ventilation
Dshumidification
Heure croissante
Heure dcroissante
Temprature de pice croissante
Temprature de pice dcroissante
Attente
C 9
R 1 4
R 1 5
1 0 5
2 2 0 k
1 0 0 k
R 1 1
1 5 0 k X 2
3 2 . 7 6 8
k H z
X 1
9 1 0 k H z
R 1 6
C 6
C 7
1 0 0 k
1 0 4
1 0 4
C 3
C 4
C 5
R 1 2
2 2 0 p
1 8 p
2 2 p
2 2 0 k
D2
D3
Jour ¥ heure actuelle
Annulation
93