[Outdoor unit installation]
¥ The pipe connection ports of the outdoor unit and connectable indoor units are shown below. (Connection of the compressors
is as shown below.)
AM-70QH4
¥ To the outdoor unit, up to three indoor units can be connected until the total value of each unit's capacity from 5.0kW to 11.0kW.
AM-80QH4
¥ To the outdoor unit, up to four indoor units can be connected until the total value of each unitÕs capacity reaches 12.0kW.
However, install indoor units so that total capacity of Indoor unit 1 and Indoor unit 2 and total capacity of Indoor unit 3 and Indoor
unit 4 are approached. For example, when two 2.5kW units and two 3.5kW units are to be connected, connect as shown below.
¥ Connect 3 or more indoor units. If only two units are to be connected, connect them as Indoor unit 1 and Indoor unit 2 or Indoor unit
3 and Indoor unit 4. However, when two 3.5kW units are connected or when one 2.5kW unit and one 4kW unit are connected,
capacity may be less than indicated capacity.
2.5kW
Indoor unit 1
Indoor unit 2
3.5kW
2.5kW
Indoor unit 3
3.5kW
Indoor unit 4
¥ Remove electric box cover and three cord bands.
Then, remove side panel and front panel in sequence.
(If side panel cannot be removed at this time, remove top
cover.)
¿6.35 (1/4")
One unit of 2.5kW, or
3.5kW
¿9.52 (3/8")
¿6.35 (1/4")
One unit of 2.5kW,
3.5kW or 4.0kW
¿9.52 (3/8")
¿6.35 (1/4")
One unit of 2.5kW, 3.5kW, 4.0kW or 5.0kW
(5kW unit: Optional flare adaptor for piping is necessary.)
¿9.52 (3/8")
¿6.35 (1/4")
One unit of 2.5kW or 3.5kW
¿9.52 (3/8")
¿6.35 (1/4")
One unit of 2.5kW, 3.5kW, 4.0kW or 5.0kW
¿9.52 (3/8")
(5kW unit: Optional flare adaptor for piping is necessary.)
¿6.35 (1/4")
One unit of 2.5kW or 3.5kW
¿9.52 (3/8")
¿6.35 (1/4")
One unit of 2.5kW, 3.5kW, 4.0kW or 5.0kW
(5kW unit: Optional flare adaptor for piping is necessary.)
¿9.52 (3/8")
Total 7.0kW
Install so that both total capacities are approached.
Total 7.0kW
Flare adaptor for piping
The flare adaptor for piping is
required
depending
combination of indoor units.
¥ ¿9.52 (3/8")
¿12.7 (1/2")
parts number HFD43D-4 001
Total capacity of 4 units:
12.0kW or less
200mm or more
100mm or more
500mm or more
74
on
100mm or more
200mm or more
Keep as far away as possible.