NSTALLAT ON
Height difference
RAM-70QH4
Height difference between indoor units
should be not more than 5m.
Indoor unit Indoor unit Indoor unit
Outdoor unit
RAM-80QH4
Height difference between indoor units
should be not more than 5m.
Indoor unit Indoor unit Indoor unit Indoor unit
Outdoor unit
RAM-70QH4
Outdoor unit
(Within
±10m)
Maximum piping length for one indoor unit is 25m.
* Additional charge of refrigerant is not required.
RAM-80QH4
Outdoor unit
(Within
±10m)
Maximum piping length for one indoor unit is 25m.
* Additional charge of refrigerant is not required.
72
Piping length
Indoor unit 1 Indoor unit 2 Indoor unit 3
L
1
L
+ L
+ L
= Maximum 60m
1
2
3
(However, L
+ L
= Maximum 35m)
1
2
Indoor unit 1 Indoor unit 2
L
L
1
2
( L
+ L
) = ( L
+ L
) = Maximum 35m
1
2
3
4
L
L
2
3
Indoor unit 3 Indoor unit 4
L
L
4
3